The pilot is designed for difficult
operating conditions. This new and
unique pilot is the solution to chronic
operating and control problems caused by
erratic pilot performance. It will
ignite and maintain stable flame in air
velocities in excess of 6000 feet per
minute. Can be used on any gas-oil or
dual fuel burner system - boilers-
dryers - rotary kilns - direct fired
heaters - supplementary fired waste heat
boilers or any other combustion
application where constant dependability
is a requirement. Can be operated with
low or high pressure gas systems, using
natural gas, propane, butane, or other
hydrocarbon gases, and will meet
O.S.H.A. requirements.
BALANCED DESIGN SOLVES PILOT STABILITY
PROBLEMS
The
patented aerodynamic principal that
makes the CCS&ES Pilot stable, and
prevents pilot flame-outs, is a new
design break-through. Due to this unique
design, the air velocity on the outside
of the pilot assembly and the air that
passes through the pilot assembly is in
a constant differential balance. Any
sudden changes in air velocities on the
outside of the pilot assembly will cause
the same relative change inside of the
pilot assembly, thus the constant
differential is maintained and the
CCS&ES Pilot will remain stable with no
possibility of flame-out.
The
CCS&ES Pilot is a raw gas pilot, with an
extended venturi mixing head assembly.
This design is not subject to clogging
by foreign material in the air stream.
CCS&ES Pilots have been operating in
difficult and dirty installations for
years with little or no maintenance
problems. Air velocities in excess of
6000 FPM, which are encountered in some
large boiler burner systems, present no
problem for the CCS&ES Pilot. Even under
these operating conditions, the CCS&ES
Pilot will provide a smooth, fast light
off of main burner system.
The
lighting efficiency of the main burner
is exceptional because of the hot pilot
flame and a steady fire during the
initial critical light off period. The
CCS&ES Pilot does not require a pilot
pressure regulator. Select the proper
model and orifice size according to your
burner's requirements and the plant gas
pressure. Each pilot will maintain a
dependable flame over the range of
pressure indicated in the curve on the
spec. sheet. The pilot gas supply line
must have a line filter or "Y" strainer
in same as indicated in the installation
instructions.
The flame
safeguard specialist will be most
interested in the flame sensing
procedure using the CCS&ES Pilot. We
recommend the UV sensor for the majority
of applications. The flame rod may be
used for lower velocities and those
applications where UV does not apply.
The pilot
flame should be scanned just ahead of
the pilot according to gas pressures and
air velocities of the system.
The
installer can use good judgment in
installation so that the pilot flame
cuts across the main flame pattern and
the pilot burner itself is out of the
main flame. Specific applications and
suggestions are available from the
distributor.
We recommend that the air source for the
pilot be from the back of the pilot for
best operation.

CCS&ES AIR-COOLED IGNITION SYSTEMS
NEW CCS&ES Retractable Air Cooled
Ignition System with heat releases from
50,000 BTU/Hr, up to and exceeding
15,000,000 BTU/Hr - for Kilns, Dryers, C
0 Furnaces, High Pressure Direct Fired
Heaters, Sulphur Recovery Units, Power
Plant Utility Boilers, etc. - Will
operate
on natural gas, butane, or
propane.
SIZE & SPECIFICATION CHART
|
MODEL |
CCS
P-2 |
CCS
P-1 |
CCS
PS-4 |
CCS
PS-6 |
|
ILLUSTRATION |
 |
 |
 |
 |
|
|
|
|
|
|
GAS INPUT
AND
BTU OUTPUT |
2 PSI to 30 PSI
22,500 to 90,000 BTU
2" WC to 30" WC
30,000 to 118,000 BTU
|
2 PSI to 30
PSI
65,000 to 265,000 BTU
2" WC to 30" WC
48,000 to 190,000 BTU
|
2 PSI to 30
PSI
100,000 to 500,000 BTU |
2 PSI to 30
PSI
200,000 to 1,000,000 BTU |
|
|
|
|
|
|
CONSTRUCTION |
Stainless through Inconel
|
Stainless
through Inconel
|
Stainless
through Inconel
|
Stainless
through Inconel
|
|
|
|
|
|
|
RECOMMENDED
BURNER SIZE |
500,000 to 15,000,00 |
10,000,000
to 50,000,000 |
35,000,000
to 100,000,000 |
100,000,000
up |
|
|
|
|
|
|
PERFORMANCE
CURVE
(CHARTS
BASED ON
1000
BTU/CU. FT.
&
0.64 SO. GR.
NAT. GAS) |
 |
 |
 |
 |
|
|
|
|
|
 |
 |
PS-6 AND PS-4 Models were
especially designed to
handle smooth, reliable light
off of utility boilers,
cement kilns, soda ash dryers,
alfalfa dryers and
other large burners.
|